| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An Improper Restriction of Excessive Authentication Attempts issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. There are no penalties for repeatedly entering incorrect passwords. |
| IBM InfoSphere Master Data Management - Collaborative Edition 11.5 could allow an unauthorized user to download reports without authentication. IBM X-Force ID: 129892. |
| An improper restriction of excessive authentication attempts vulnerability in /principals in Synology CardDAV Server before 6.0.7-0085 allows remote attackers to obtain user credentials via a brute-force attack. |
| Weak access control methods on the TP-Link TL-SG108E 1.0.0 allow any user on a NAT network with an authenticated administrator to access the device without entering user credentials. The authentication record is stored on the device; thus if an administrator authenticates from a NAT network, the authentication applies to the IP address of the NAT gateway, and any user behind that NAT gateway is also treated as authenticated. |
| Weak access controls in the Device Logout functionality on the TP-Link TL-SG108E v1.0.0 allow remote attackers to call the logout functionality, triggering a denial of service condition. |
| Trustwave Secure Web Gateway (SWG) through 11.8.0.27 allows remote attackers to append an arbitrary public key to the device's SSH Authorized Keys data, and consequently obtain remote root access, via the publicKey parameter to the /sendKey URI. |
| The 'Find Phone' function in Nice smartphones with software versions earlier before Nice-AL00C00B0135 has an authentication bypass vulnerability. An unauthenticated attacker may wipe and factory reset the phone by special steps. Due to missing authentication of the 'Find Phone' function, an attacker may exploit the vulnerability to bypass the 'Find Phone' function in order to use the phone normally. |
| A privilege escalation vulnerability in the Secure Shell (SSH) subsystem in the StarOS operating system for Cisco ASR 5000 Series, ASR 5500 Series, ASR 5700 Series devices, and Cisco Virtualized Packet Core could allow an authenticated, remote attacker to gain unrestricted, root shell access. The vulnerability is due to missing input validation of parameters passed during SSH or SFTP login. An attacker could exploit this vulnerability by providing crafted user input to the SSH or SFTP command-line interface (CLI) during SSH or SFTP login. An exploit could allow an authenticated attacker to gain root privileges access on the router. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability can be triggered via both IPv4 and IPv6 traffic. An established TCP connection toward port 22, the SSH default port, is needed to perform the attack. The attacker must have valid credentials to login to the system via SSH or SFTP. The following products have been confirmed to be vulnerable: Cisco ASR 5000/5500/5700 Series devices running StarOS after 17.7.0 and prior to 18.7.4, 19.5, and 20.2.3 with SSH configured are vulnerable. Cisco Virtualized Packet Core - Single Instance (VPC-SI) and Distributed Instance (VPC-DI) devices running StarOS prior to N4.2.7 (19.3.v7) and N4.7 (20.2.v0) with SSH configured are vulnerable. Cisco Bug IDs: CSCva65853. |
| Apache OpenMeetings 1.0.0 uses not very strong cryptographic storage, captcha is not used in registration and forget password dialogs and auth forms missing brute force protection. |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |
| A Missing Authentication for Critical Function issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. An attacker may create an application user account to gain administrative privileges. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| IBM BigFix Compliance (TEMA SUAv1 SCA SCM) uses an inadequate account lockout setting that could allow a remote attacker to brute force account credentials. IBM X-Force ID: 123672. |
| phpMyFAQ before 2.9.8 does not properly mitigate brute-force attacks that try many passwords in attempted logins quickly. |
| A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. |
| Nextcloud Server before 9.0.54 and 10.0.1 & ownCloud Server before 9.1.2, 9.0.6, and 8.2.9 suffer from SMB User Authentication Bypass. Nextcloud/ownCloud include an optional and not by default enabled SMB authentication component that allows authenticating users against an SMB server. This backend is implemented in a way that tries to connect to a SMB server and if that succeeded consider the user logged-in. The backend did not properly take into account SMB servers that have any kind of anonymous auth configured. This is the default on SMB servers nowadays and allows an unauthenticated attacker to gain access to an account without valid credentials. Note: The SMB backend is disabled by default and requires manual configuration in the Nextcloud/ownCloud config file. If you have not configured the SMB backend then you're not affected by this vulnerability. |
| A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device. |
| The admin terminal in Hawt.io does not require authentication, which allows remote attackers to execute arbitrary commands via the k parameter. |